Method
Discrete method, single line
Composition
Analyzer
Data processor
Sample Types
Serum, urine, plasma
Remark
Sample availability is defined by the sample viscosity.
Item Numbers for Simultaneous Analysis
A Maximum of 60 items (A maximum of 63 items with ISE option)
Maximum Reagent Bottle Numbers
76 bottles (the total of first reagent and second reagent)
Throughput
A maximum of 400 tests/hour (A maximum of 800 tests/hour with ISE option)
Remark
400 samples/hour can be processed when performing 1item/sample continuous order.
200 samples/hour can be processed when performing ISE item only.
Analysis Method
1. Photometric method
• End-point method
• Rate method
• Fixed method
2. Electrode method (ISE option)
Reaction Liquid Volume
90 μL ~ 350 μL
Reaction Time
R1 S R2
P0 P1 P10 P11 P27
40.5sec 3min 27sec 5min 10.5sec
8min 37.5sec
Reaction Temperature
37 °C (± 0.3 °C)
Items can be Analyzed
1. Protein, colloid reaction
Total protein, albumin, TTT, ZTT
2. Enzymes and other related substances
CK, CK-MB, AST, ALT, LDH, ALP, γGTP, MAO, CHE, guanase, ADA, LAP, AMY, lipase,
ACP, TR-ACP, HBD, NAG
3. Low molecular nitrogen compound
Creatine, creatinine, UA, UN
4. Glucide and other related substances
Glucose, fructosamine, sialic acid
5. Lipid and other related substances
TG, phospholipids, NEFA, cholesterol, free cholesterol, HDL-C, total bile acid,
apolipoprotein, β-lipoprotein
6. Electrolytes
Mg, Ca, IP (Na, K, Cl with ISE option)
7. Biological trace metals
Fe, TIBC, UIBC, Cu
8. Biological dye-related substances
Total bilirubin, direct bilirubin, indirect bilirubin
9. Drugs
Phenobaribital, phenytoin, carbamazepine, valproic acid, primidone, teophylline
10. Immunoglobuline
IgG, IgA, IgM
11. Complements and other related substances
C3, C4
12. Plasma protein
CRP, ferritin, Tf
13. Tumor-related antigens
CEA, AFP
14. Serum information
Icterus, hemolysis, lipemia
Remark
The items listed above are examples of items that can be measured.
Serum Information
Graded index indications are possible by measuring the degree of icterus, hemolysis, and lipemia.
Remark
• The judgment levels are user defined.
• The degree of incidence can be displayed and saved to the analyzed data as a flag.
Reception of Analysis Requests
1. Combination of individual input and batch input is possible for item selection.
2. Input operation
• Touchscreen
• Pointing device
• Keyboard
• Online
3. Maximum number of requested samples
9999 samples/index
4. Maximum of 63 items can be ordered per specimen, including ISE option (when installed). When
a separate reagent for LIH is used, the maximum number of ordered tests per sample is inclusive
of LIH.
5. Patient information can be entered separately from item selection.
Sample Search
1. It is possible to check for the sample status by sample ID and sample No. for received samples.
2. Displays the estimated time to results output for a sample in process.
Repeat Run
1. Automatic repeat run
2. Manual repeat run is possible.
3. It is possible to change the sample volume.
Normal repeat run, condensation repeat run, dilution repeat run (including pre-dilution
repeat run)
4. Reflex Testing
Remark
• A host computer instructs sample extraction and repeat run when connected.
• Reflex testing function determines additional testing items from the result of one analysis and
performs further analysis.
Warm Up and Standby
1. The warm-up time is 20 minutes.
2. Automatic power ON/OFF is available.
Remark
The automatic power ON/OFF function does not control the water tap.
Input Method
1. Touchscreen
2. Pointing device
3. Keyboard
4. Online
Monitor Display
Japan: Japanese
Other than Japan: 13 languages will be applied
Output Method
1. Monitor display
2. Hard disk
3. Online
4. External storage device (Option)
5. Printout (Option)
STAT Operation (STAT table)
1. Starting analysis by simple operation is possible.
2. Interruption is possible between tests.
Remark
Automatic repeat run function for samples with barcodes is possible.
Communication System
Communication with HIS/LIS
The following functions are prospective options (Note 1):
1. PRO Service via an internet connection
Note 1
For accounting and remote service systems
Sample Pre-Dilution Analysis
1. Sample dilution factor: 3, 5, 10, 15, 20, 25, 50, 75, 100 fixed
2. Diluent: User setting is possible (Only one type)
3. This can be performed during normal analysis.
Safety and Crash Detection
1. Crash detection function is available for sample and reagent transfer mechanisms.
2. Function to prevent users from touching the probe end accidentally (setting up walls etc.) is
available.
Reliability
Sample probe clot detection function
Machines we support for service, maintenance, repair and installation
Beckman coulter chemistry analyzer: AU 5800, AU 680, AU 480, DXC 800, DXC 600,LX20
OLYMPUS chemistry analyzer : AU 5400, AU 2700, AU 640, AU 400
Abbott Elisa analyzer: ARCHITECT i1000 SR, ARCHITECT i2000 SR
Beckman Coulter Access 2
Horiba Pentra C400 Biochemistry
Dynex Technologies : DSX Automated ELISA System
ELISA Instruments : Dynex Reader, Washer. Seac Alisei Automatic Elisa Analyser, Seac Brio semi Automatic Elisa Analyser, Biotec Elx 800 Reader, Elx 50 Washer, Grifols Triturus Automatic Elisa Analyser, Euroimmun ANA 1 Elisa analyser, Orgentec Alegria elisa analyser.
Urine Instruments: Iq 200 Urine Analyser ( Arkray and Velocity models )